Version: dev

WRFWeselyParameters

Numeric constants of WRF-Chem's Wesely dry-deposition scheme, transcribed from chem/module_dep_simple.F of WRF v4.8.0. Several are places where the AtmosphericDeposition.jl-derived component in EarthSciModels differs; those are called out in the individual descriptions.

Domain
atmospheric_deposition
Subdomain
wrf_wesely
Type
model
.esm schema
1.1.0
Source
components/atmospheric_deposition/wrf_wesely/wesely_parameters.esm
Tags
#atmospheric_deposition #wrf_wesely #model

Description

Numeric constants of WRF-Chem’s Wesely dry-deposition scheme, transcribed from chem/module_dep_simple.F of WRF v4.8.0. Several are places where the AtmosphericDeposition.jl-derived component in EarthSciModels differs; those are called out in the individual descriptions.

Parameters

NameUnitsDefaultDescription
t_celsiusK273.15Celsius offset, tc = t - 273.15 (module_dep_simple.F:940). The AtmosphericDeposition.jl-derived component uses 273.0, a systematic 0.15 K shift in every temperature threshold.
t_refK298.0Reference temperature of the Henry’s law correction, REAL, parameter :: t0 = 298. (:923).
rs_rad_numW/m^2200.0Numerator of the stomatal radiation term, z = 200./(rad+0.1).
rs_rad_epsW/m^20.1The +0.1 guard in z = 200./(rad+0.1). NOT +1.0: at rad = 10 W/m^2 the difference in rs is 15.6 percent.
rs_t_numK^2400.0Numerator of the stomatal temperature term, 400./(tc (40-tc)).
rs_t_hiK40.0Upper temperature of the stomatal window. At or above it rs = 9999; the AtmosphericDeposition.jl-derived component omits this clamp and produces a NEGATIVE rs above 40 C.
r_bigs/m9999.0Stomatal resistance outside the 0-40 C window.
rdc_as/m100.0Leading coefficient of rdc = 100 (1 + 1000/(rad+10)) / (1 + 1000 rdtheta).
rdc_bW/m^21000.0Radiation coefficient of rdc.
rdc_cW/m^210.0Radiation offset of rdc.
rluo1_rs/m3000.0The 1/3000 term of rluo1, the O3 cuticle resistance under DEW.
rluo2_rs/m1000.0The 1/1000 term of rluo2, the O3 cuticle resistance under RAIN.
rluo_mult13.0The factor 3 that appears in BOTH spellings of the cuticle conductance – as 3./rlu in rluo1/rluo2 (:963-964) and as 1./(3.*rlu) in the general wet/rain branch (:1031,:1034). Those two are NOT the same thing and differ by a factor of 9; see FORTRAN_BUGS B4. This component transcribes each site as WRF spells it.
resice_as/m1000.0Amplitude of the ice resistance, resice = 1000 exp(-(tc+4)).
resice_bK4.0Offset of the ice resistance. Applied UNCONDITIONALLY by WRF, not gated on tc < 0.
resice_tscaleK1.0Temperature scale of the ice resistance’s exponent, resice = 1000 exp(-(tc+4)/(1 K)). WRF writes exp(-(tc+4.)) with tc in degrees C; this 1 K reference only makes the exponent dimensionless and does not change any value.
rmx_h(M/atm)/(m/s)3000.0Henry’s law divisor of the mesophyll resistance, rmx = 1/(hstary/3000 + 100 f0). Carries (M/atm)/(m/s) so that hstary/rmx_h is a conductance in m/s; the value is WRF’s 3000 unchanged.
rmx_fm/s100.0Reactivity coefficient of the mesophyll resistance. Carries m/s so that rmx_f f0 is a conductance and rmx = 1/(hstary/rmx_h + rmx_f f0) comes out in s/m.
hstar_scale1/(M/atm)1e-05The 1.e-5 multiplying hstary in rclx, rgsx and the dry rlux.
hstar_scale_wet(m/s)/(M/atm)1e-07The 1.e-7 multiplying hstary in the wet and rain rlux, 1/rlux = 1/(3 rlu) + 1.e-7 hstary + f0/rluo1: every other term is a conductance, so Wesely’s (1989) empirical coefficient carries (m/s)/(M/atm). Declared 1/(M/atm) until 2026-11-12, which the esm 2.1 validator rejected as adding a dimensionless term to conductances; the number is unchanged. (The dry 1.e-5, hstar_scale, sits inside a dimensionless bracket and is correctly 1/(M/atm).)
rc_floors/m1.0Floor on Rc, rcx(n) = max( 1.,rcx(n) ). There is NO ceiling: WRF’s Rc for NO reaches 5.6e9 s/m. The AtmosphericDeposition.jl-derived component clamps to [10, 9999], which is 10x too large for HNO3 and about a million times too small for the insoluble unreactive gases.
rs_t_epsK^21e-30Guard keeping the discarded stomatal branch finite where its denominator tc (40 - tc) vanishes (tc = 0 or 40), so it carries that denominator’s K^2. Split on 2026-11-12 from the dimensionless rc_eps, which the esm 2.1 validator rejected against both of its uses.
hstar_epsM/atm1e-30Floor keeping a discarded branch finite for a gas with hstar = 0, so it carries hstary’s M/atm. Split on 2026-11-12 from the dimensionless rc_eps.
o3_rac_caps/m100.0Cap on the in-canopy resistance in the OZONE branch only, min(100., rac) (:1054). For deciduous midsummer rac = 2000, so this is a factor of 7.3 on the ground-path conductance.
p_o316.0Gas index of O3 for chem_opt = 101.
p_so212.0Gas index of SO2.
usgs_water116.0USGS land-use category of water, iswater_temp = 16 (:19).
usgs_ice124.0USGS land-use category of permanent ice, isice_temp = 24 (:18).
season_snow14.0Seasonal category 4, ‘winter with snow’. Note that for every non-MOZART mechanism wesely_driver only ever produces iseason 1 or 2 (FORTRAN_BUGS B7), so this branch is unreachable in a RADM2 run; it is transcribed because the kernel sweep can reach it.
tc_warmK-1.0The -1 C threshold shared by the SO2 cuticle, the SO2/NH3 snow branches and the NH3 winter branches.
tc_coldK-5.0The -5 C threshold below which the SO2 cuticle and the NH3 winter branches take their coldest value.
so2_rh_split%81.3Relative humidity at which the SO2 cuticle resistance switches expression.
so2_rh_a1s/m25000.0Amplitude below 81.3 percent RH, rlux = 25000 exp(-0.0693 rh).
so2_rh_b11/%-0.0693Exponent below 81.3 percent RH.
so2_rh_a2s/m580000000000.0Amplitude above 81.3 percent RH, rlux = 0.58e12 exp(-0.278 rh).
so2_rh_b21/%-0.278Exponent above 81.3 percent RH.
so2_rlux_wets/m1.0SO2 cuticle resistance on a wet or rained-on surface warmer than -1 C.
so2_rlux_cools/m200.0SO2 cuticle resistance for -5 <= tc <= -1 C.
so2_rlux_colds/m500.0SO2 cuticle resistance below -5 C.
so2_rgs_drys/m1000.0SO2 ground resistance over a dry surface.
so2_rgs_wets/m500.0SO2 ground resistance over a wet surface with ordinary NH3.
snow_tc_hiK2.0Upper temperature of the snow ramp, shared by SO2 and NH3.
snow_as/(m K)70.0Slope of the snow ramp, 70 (2 - tc).
snow_colds/m500.0Snow-covered resistance below the ramp.
nh3_cools/m200.0NH3 resistance for -5 <= tc <= -1 C in the winter branches.
nh3_verycolds/m500.0NH3 resistance below -5 C in the winter branches.
nh3_grass_summers/m1000.0NH3 over grassland in summer.
nh3_grass_days/m50.0NH3 over grassland, winter, daytime.
nh3_grass_nights/m100.0NH3 over grassland, winter, night.
nh3_grass_wets/m20.0NH3 over grassland, winter, wet.
nh3_agri_wet_ss/m50.0NH3 over agricultural land, summer, wet.
nh3_agri_night_ss/m200.0NH3 over agricultural land, summer, night.
nh3_agri_wet_ws/m100.0NH3 over agricultural land, winter, wet.
nh3_agri_night_ws/m300.0NH3 over agricultural land, winter, night.
nh3_forest_days/m500.0NH3 over forest and semi-natural, daytime.
nh3_forest_nights/m1000.0NH3 over forest and semi-natural, night.
nh3_forest_wet_his/m100.0NH3 over forest, wet, in a high-NH3 regime (chem(nh3) > 2 chem(so2)); otherwise the wet forest value is 0.
nh3_urban_drys/m50.0NH3 over urban and desert soils when dry; 0 when wet.
z_refm2.0Reference height of the deposition velocity, zr = 2.0 in landusevg (:1423 region). The 2 m value is then converted to a layer mean by cellvg; a component that evaluates the resistances at the first layer’s MID-POINT instead is answering a different question.
prandtl_7410.74The turbulent Prandtl number of the Businger heat profile, the 0.74 in every branch of polint and of cellvg’s integral. Its absence inflates Ra by 1/0.74 = 1.351.
businger_c19.0Coefficient of the unstable Businger HEAT function, (1 - 9 z/L)^(1/4). The momentum function uses 15 and carries an extra arctan term; this is not that.
busing_eps10.001The +0.001 inside ((1-9 z rmol)^0.25 + 0.001)^2.
stable_c14.7Coefficient of the stable branch, + 4.7 rmol (zr - z0).
rb_c12.0The 2.0 of depv = ustar vk/(2 scpr23 + polint); with karman = 0.4 it makes Rb = 5 scpr23/ustar.
ustar_floorm/s0.0001Floor on the friction velocity in aer_res only, max(ustar,1.0e-4).
rmol_deadband1/m1e-06Below this magnitude depvel treats 1/L as exactly zero.
cell_b10.164The 0.164/rmol coefficient of cellvg’s unstable integral.
cell_stable_c12.35The 2.35 rmol (dz-zr)^2 term of cellvg’s stable integral.
cell_eps11e-30Guard keeping a discarded cellvg branch finite when the log or square-root argument is degenerate. Dimensionless; the matching guard on rmol itself is rmol_eps. Also clamps the Businger base 1 - 9 z rmol and the log arguments (ar-1)/(ar+1), (ao-1)/(ao+1) of depvel’s unstable polint, and the (pzr - 1) denominator of cellvg’s log argument, so that the discarded branches stay finite at rmol = 0 and in stable states. None of these clamps is active on the branch actually selected (rmol < 0 gives 1 - 9 z rmol > 1, ar, ao > 1.001^2 and pzr - 1 > 0).
rmol_eps1/m1e-30Guard keeping cellvg’s discarded unstable branch finite when rmol is zero: it stands in for rmol in cell_b/rmol, so it carries rmol’s units (split from the dimensionless cell_eps on 2026-11-12, when the esm 2.1 validator rejected the ifelse mixing the two).

Raw .esm

Raw .esm JSON (this component)
{
  "variables": {
    "t_celsius": {
      "type": "parameter",
      "units": "K",
      "default": 273.15,
      "description": "Celsius offset, tc = t - 273.15 (module_dep_simple.F:940). The AtmosphericDeposition.jl-derived component uses 273.0, a systematic 0.15 K shift in every temperature threshold."
    },
    "t_ref": {
      "type": "parameter",
      "units": "K",
      "default": 298.0,
      "description": "Reference temperature of the Henry's law correction, `REAL, parameter :: t0 = 298.` (:923)."
    },
    "rs_rad_num": {
      "type": "parameter",
      "units": "W/m^2",
      "default": 200.0,
      "description": "Numerator of the stomatal radiation term, z = 200./(rad+0.1)."
    },
    "rs_rad_eps": {
      "type": "parameter",
      "units": "W/m^2",
      "default": 0.1,
      "description": "The +0.1 guard in z = 200./(rad+0.1). NOT +1.0: at rad = 10 W/m^2 the difference in rs is 15.6 percent."
    },
    "rs_t_num": {
      "type": "parameter",
      "units": "K^2",
      "default": 400.0,
      "description": "Numerator of the stomatal temperature term, 400./(tc (40-tc))."
    },
    "rs_t_hi": {
      "type": "parameter",
      "units": "K",
      "default": 40.0,
      "description": "Upper temperature of the stomatal window. At or above it rs = 9999; the AtmosphericDeposition.jl-derived component omits this clamp and produces a NEGATIVE rs above 40 C."
    },
    "r_big": {
      "type": "parameter",
      "units": "s/m",
      "default": 9999.0,
      "description": "Stomatal resistance outside the 0-40 C window."
    },
    "rdc_a": {
      "type": "parameter",
      "units": "s/m",
      "default": 100.0,
      "description": "Leading coefficient of rdc = 100 (1 + 1000/(rad+10)) / (1 + 1000 rdtheta)."
    },
    "rdc_b": {
      "type": "parameter",
      "units": "W/m^2",
      "default": 1000.0,
      "description": "Radiation coefficient of rdc."
    },
    "rdc_c": {
      "type": "parameter",
      "units": "W/m^2",
      "default": 10.0,
      "description": "Radiation offset of rdc."
    },
    "rluo1_r": {
      "type": "parameter",
      "units": "s/m",
      "default": 3000.0,
      "description": "The 1/3000 term of rluo1, the O3 cuticle resistance under DEW."
    },
    "rluo2_r": {
      "type": "parameter",
      "units": "s/m",
      "default": 1000.0,
      "description": "The 1/1000 term of rluo2, the O3 cuticle resistance under RAIN."
    },
    "rluo_mult": {
      "type": "parameter",
      "units": "1",
      "default": 3.0,
      "description": "The factor 3 that appears in BOTH spellings of the cuticle conductance -- as `3./rlu` in rluo1/rluo2 (:963-964) and as `1./(3.*rlu)` in the general wet/rain branch (:1031,:1034). Those two are NOT the same thing and differ by a factor of 9; see FORTRAN_BUGS B4. This component transcribes each site as WRF spells it."
    },
    "resice_a": {
      "type": "parameter",
      "units": "s/m",
      "default": 1000.0,
      "description": "Amplitude of the ice resistance, resice = 1000 exp(-(tc+4))."
    },
    "resice_b": {
      "type": "parameter",
      "units": "K",
      "default": 4.0,
      "description": "Offset of the ice resistance. Applied UNCONDITIONALLY by WRF, not gated on tc < 0."
    },
    "resice_tscale": {
      "type": "parameter",
      "units": "K",
      "default": 1.0,
      "description": "Temperature scale of the ice resistance's exponent, resice = 1000 exp(-(tc+4)/(1 K)). WRF writes exp(-(tc+4.)) with tc in degrees C; this 1 K reference only makes the exponent dimensionless and does not change any value."
    },
    "rmx_h": {
      "type": "parameter",
      "units": "(M/atm)/(m/s)",
      "default": 3000.0,
      "description": "Henry's law divisor of the mesophyll resistance, rmx = 1/(hstary/3000 + 100 f0). Carries (M/atm)/(m/s) so that hstary/rmx_h is a conductance in m/s; the value is WRF's 3000 unchanged."
    },
    "rmx_f": {
      "type": "parameter",
      "units": "m/s",
      "default": 100.0,
      "description": "Reactivity coefficient of the mesophyll resistance. Carries m/s so that rmx_f f0 is a conductance and rmx = 1/(hstary/rmx_h + rmx_f f0) comes out in s/m."
    },
    "hstar_scale": {
      "type": "parameter",
      "units": "1/(M/atm)",
      "default": 1e-05,
      "description": "The 1.e-5 multiplying hstary in rclx, rgsx and the dry rlux."
    },
    "hstar_scale_wet": {
      "type": "parameter",
      "units": "(m/s)/(M/atm)",
      "default": 1e-07,
      "description": "The 1.e-7 multiplying hstary in the wet and rain rlux, 1/rlux = 1/(3 rlu) + 1.e-7 hstary + f0/rluo1: every other term is a conductance, so Wesely's (1989) empirical coefficient carries (m/s)/(M/atm). Declared 1/(M/atm) until 2026-11-12, which the esm 2.1 validator rejected as adding a dimensionless term to conductances; the number is unchanged. (The dry 1.e-5, hstar_scale, sits inside a dimensionless bracket and is correctly 1/(M/atm).)"
    },
    "rc_floor": {
      "type": "parameter",
      "units": "s/m",
      "default": 1.0,
      "description": "Floor on Rc, `rcx(n) = max( 1.,rcx(n) )`. There is NO ceiling: WRF's Rc for NO reaches 5.6e9 s/m. The AtmosphericDeposition.jl-derived component clamps to [10, 9999], which is 10x too large for HNO3 and about a million times too small for the insoluble unreactive gases."
    },
    "rs_t_eps": {
      "type": "parameter",
      "units": "K^2",
      "default": 1e-30,
      "description": "Guard keeping the discarded stomatal branch finite where its denominator tc (40 - tc) vanishes (tc = 0 or 40), so it carries that denominator's K^2. Split on 2026-11-12 from the dimensionless rc_eps, which the esm 2.1 validator rejected against both of its uses."
    },
    "hstar_eps": {
      "type": "parameter",
      "units": "M/atm",
      "default": 1e-30,
      "description": "Floor keeping a discarded branch finite for a gas with hstar = 0, so it carries hstary's M/atm. Split on 2026-11-12 from the dimensionless rc_eps."
    },
    "o3_rac_cap": {
      "type": "parameter",
      "units": "s/m",
      "default": 100.0,
      "description": "Cap on the in-canopy resistance in the OZONE branch only, min(100., rac) (:1054). For deciduous midsummer rac = 2000, so this is a factor of 7.3 on the ground-path conductance."
    },
    "p_o3": {
      "type": "parameter",
      "units": "1",
      "default": 6.0,
      "description": "Gas index of O3 for chem_opt = 101."
    },
    "p_so2": {
      "type": "parameter",
      "units": "1",
      "default": 2.0,
      "description": "Gas index of SO2."
    },
    "usgs_water": {
      "type": "parameter",
      "units": "1",
      "default": 16.0,
      "description": "USGS land-use category of water, `iswater_temp = 16` (:19)."
    },
    "usgs_ice": {
      "type": "parameter",
      "units": "1",
      "default": 24.0,
      "description": "USGS land-use category of permanent ice, `isice_temp = 24` (:18)."
    },
    "season_snow": {
      "type": "parameter",
      "units": "1",
      "default": 4.0,
      "description": "Seasonal category 4, 'winter with snow'. Note that for every non-MOZART mechanism wesely_driver only ever produces iseason 1 or 2 (FORTRAN_BUGS B7), so this branch is unreachable in a RADM2 run; it is transcribed because the kernel sweep can reach it."
    },
    "tc_warm": {
      "type": "parameter",
      "units": "K",
      "default": -1.0,
      "description": "The -1 C threshold shared by the SO2 cuticle, the SO2/NH3 snow branches and the NH3 winter branches."
    },
    "tc_cold": {
      "type": "parameter",
      "units": "K",
      "default": -5.0,
      "description": "The -5 C threshold below which the SO2 cuticle and the NH3 winter branches take their coldest value."
    },
    "so2_rh_split": {
      "type": "parameter",
      "units": "%",
      "default": 81.3,
      "description": "Relative humidity at which the SO2 cuticle resistance switches expression."
    },
    "so2_rh_a1": {
      "type": "parameter",
      "units": "s/m",
      "default": 25000.0,
      "description": "Amplitude below 81.3 percent RH, rlux = 25000 exp(-0.0693 rh)."
    },
    "so2_rh_b1": {
      "type": "parameter",
      "units": "1/%",
      "default": -0.0693,
      "description": "Exponent below 81.3 percent RH."
    },
    "so2_rh_a2": {
      "type": "parameter",
      "units": "s/m",
      "default": 580000000000.0,
      "description": "Amplitude above 81.3 percent RH, rlux = 0.58e12 exp(-0.278 rh)."
    },
    "so2_rh_b2": {
      "type": "parameter",
      "units": "1/%",
      "default": -0.278,
      "description": "Exponent above 81.3 percent RH."
    },
    "so2_rlux_wet": {
      "type": "parameter",
      "units": "s/m",
      "default": 1.0,
      "description": "SO2 cuticle resistance on a wet or rained-on surface warmer than -1 C."
    },
    "so2_rlux_cool": {
      "type": "parameter",
      "units": "s/m",
      "default": 200.0,
      "description": "SO2 cuticle resistance for -5 <= tc <= -1 C."
    },
    "so2_rlux_cold": {
      "type": "parameter",
      "units": "s/m",
      "default": 500.0,
      "description": "SO2 cuticle resistance below -5 C."
    },
    "so2_rgs_dry": {
      "type": "parameter",
      "units": "s/m",
      "default": 1000.0,
      "description": "SO2 ground resistance over a dry surface."
    },
    "so2_rgs_wet": {
      "type": "parameter",
      "units": "s/m",
      "default": 500.0,
      "description": "SO2 ground resistance over a wet surface with ordinary NH3."
    },
    "snow_tc_hi": {
      "type": "parameter",
      "units": "K",
      "default": 2.0,
      "description": "Upper temperature of the snow ramp, shared by SO2 and NH3."
    },
    "snow_a": {
      "type": "parameter",
      "units": "s/(m K)",
      "default": 70.0,
      "description": "Slope of the snow ramp, 70 (2 - tc)."
    },
    "snow_cold": {
      "type": "parameter",
      "units": "s/m",
      "default": 500.0,
      "description": "Snow-covered resistance below the ramp."
    },
    "nh3_cool": {
      "type": "parameter",
      "units": "s/m",
      "default": 200.0,
      "description": "NH3 resistance for -5 <= tc <= -1 C in the winter branches."
    },
    "nh3_verycold": {
      "type": "parameter",
      "units": "s/m",
      "default": 500.0,
      "description": "NH3 resistance below -5 C in the winter branches."
    },
    "nh3_grass_summer": {
      "type": "parameter",
      "units": "s/m",
      "default": 1000.0,
      "description": "NH3 over grassland in summer."
    },
    "nh3_grass_day": {
      "type": "parameter",
      "units": "s/m",
      "default": 50.0,
      "description": "NH3 over grassland, winter, daytime."
    },
    "nh3_grass_night": {
      "type": "parameter",
      "units": "s/m",
      "default": 100.0,
      "description": "NH3 over grassland, winter, night."
    },
    "nh3_grass_wet": {
      "type": "parameter",
      "units": "s/m",
      "default": 20.0,
      "description": "NH3 over grassland, winter, wet."
    },
    "nh3_agri_wet_s": {
      "type": "parameter",
      "units": "s/m",
      "default": 50.0,
      "description": "NH3 over agricultural land, summer, wet."
    },
    "nh3_agri_night_s": {
      "type": "parameter",
      "units": "s/m",
      "default": 200.0,
      "description": "NH3 over agricultural land, summer, night."
    },
    "nh3_agri_wet_w": {
      "type": "parameter",
      "units": "s/m",
      "default": 100.0,
      "description": "NH3 over agricultural land, winter, wet."
    },
    "nh3_agri_night_w": {
      "type": "parameter",
      "units": "s/m",
      "default": 300.0,
      "description": "NH3 over agricultural land, winter, night."
    },
    "nh3_forest_day": {
      "type": "parameter",
      "units": "s/m",
      "default": 500.0,
      "description": "NH3 over forest and semi-natural, daytime."
    },
    "nh3_forest_night": {
      "type": "parameter",
      "units": "s/m",
      "default": 1000.0,
      "description": "NH3 over forest and semi-natural, night."
    },
    "nh3_forest_wet_hi": {
      "type": "parameter",
      "units": "s/m",
      "default": 100.0,
      "description": "NH3 over forest, wet, in a high-NH3 regime (chem(nh3) > 2 chem(so2)); otherwise the wet forest value is 0."
    },
    "nh3_urban_dry": {
      "type": "parameter",
      "units": "s/m",
      "default": 50.0,
      "description": "NH3 over urban and desert soils when dry; 0 when wet."
    },
    "z_ref": {
      "type": "parameter",
      "units": "m",
      "default": 2.0,
      "description": "Reference height of the deposition velocity, `zr = 2.0` in landusevg (:1423 region). The 2 m value is then converted to a layer mean by cellvg; a component that evaluates the resistances at the first layer's MID-POINT instead is answering a different question."
    },
    "prandtl_74": {
      "type": "parameter",
      "units": "1",
      "default": 0.74,
      "description": "The turbulent Prandtl number of the Businger heat profile, the 0.74 in every branch of polint and of cellvg's integral. Its absence inflates Ra by 1/0.74 = 1.351."
    },
    "businger_c": {
      "type": "parameter",
      "units": "1",
      "default": 9.0,
      "description": "Coefficient of the unstable Businger HEAT function, (1 - 9 z/L)^(1/4). The momentum function uses 15 and carries an extra arctan term; this is not that."
    },
    "busing_eps": {
      "type": "parameter",
      "units": "1",
      "default": 0.001,
      "description": "The +0.001 inside ((1-9 z rmol)^0.25 + 0.001)^2."
    },
    "stable_c": {
      "type": "parameter",
      "units": "1",
      "default": 4.7,
      "description": "Coefficient of the stable branch, + 4.7 rmol (zr - z0)."
    },
    "rb_c": {
      "type": "parameter",
      "units": "1",
      "default": 2.0,
      "description": "The 2.0 of depv = ustar vk/(2 scpr23 + polint); with karman = 0.4 it makes Rb = 5 scpr23/ustar."
    },
    "ustar_floor": {
      "type": "parameter",
      "units": "m/s",
      "default": 0.0001,
      "description": "Floor on the friction velocity in aer_res only, max(ustar,1.0e-4)."
    },
    "rmol_deadband": {
      "type": "parameter",
      "units": "1/m",
      "default": 1e-06,
      "description": "Below this magnitude depvel treats 1/L as exactly zero."
    },
    "cell_b": {
      "type": "parameter",
      "units": "1",
      "default": 0.164,
      "description": "The 0.164/rmol coefficient of cellvg's unstable integral."
    },
    "cell_stable_c": {
      "type": "parameter",
      "units": "1",
      "default": 2.35,
      "description": "The 2.35 rmol (dz-zr)^2 term of cellvg's stable integral."
    },
    "cell_eps": {
      "type": "parameter",
      "units": "1",
      "default": 1e-30,
      "description": "Guard keeping a discarded cellvg branch finite when the log or square-root argument is degenerate. Dimensionless; the matching guard on rmol itself is rmol_eps. Also clamps the Businger base 1 - 9 z rmol and the log arguments (ar-1)/(ar+1), (ao-1)/(ao+1) of depvel's unstable polint, and the (pzr - 1) denominator of cellvg's log argument, so that the discarded branches stay finite at rmol = 0 and in stable states. None of these clamps is active on the branch actually selected (rmol < 0 gives 1 - 9 z rmol > 1, ar, ao > 1.001^2 and pzr - 1 > 0)."
    },
    "rmol_eps": {
      "type": "parameter",
      "units": "1/m",
      "default": 1e-30,
      "description": "Guard keeping cellvg's discarded unstable branch finite when rmol is zero: it stands in for rmol in `cell_b/rmol`, so it carries rmol's units (split from the dimensionless cell_eps on 2026-11-12, when the esm 2.1 validator rejected the ifelse mixing the two)."
    }
  },
  "equations": []
}